Item
|
Characteristics
|
|
Operating Temperature Range
|
-40~+85ºC
|
|
Rated Working Voltage Range
|
6.3V~50V DC
|
|
Capacitance Tolerance (120Hz, 25ºC)
|
±20%(M)
|
|
Leakage Current ( 25ºC)
|
I 0.002CV
or 0.4(µA)
I:Leakage Current (µA)
C:Rated Capacitance (µF)
V:Working Voltage (V)
After 3 minutes applying the DC working voltage
|
|
Surge Voltage (25ºC)
|
|
W.V.
|
6.3
|
10
|
16
|
25
|
35
|
50
|
|
S.V.
|
8
|
13
|
20
|
32
|
44
|
63
|
|
|
Dissipation Factor (120Hz, 25ºC)
(Tan. )
|
|
W.V.
|
6.3
|
10
|
16
|
25
|
35
|
50
|
|
Tan.
|
0.25
|
0.20
|
0.17
|
0.15
|
0.12
|
0.10
|
|
|
Temperature Characteristics
|
|
W.V.
|
6.3
|
10
|
16
|
25
|
35
|
50
|
63
|
|
-25ºC/+25ºC
|
5
|
4
|
3
|
3
|
2
|
2
|
2
|
|
-40ºC/+25ºC
|
10
|
8
|
6
|
4
|
3
|
3
|
3
|
Impedance
ration at 120Hz
|
|
Load Test
|
After 1000 hours
application of W.V. at +85ºC
the capacitor shall meet the following limits
|
Capacitance
change
|
± 20% of initial value
|
|
Tan.
|
200% of initial
specified value
|
|
Leakage current
|
initial specified
value
|
|
|
Shelf Test
|
After 500 hours
application of W.V. at +85ºC
the capacitor shall meet the following limits
|
Capacitance
change
|
± 20% of initial value
|
|
Tan.
|
200% of initial
specified value
|
|
Leakage current
|
200% of initial
specified value
|
|